Polokalama Faaliliu

  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll poʻo le faʻasalalauga faʻapitoa ile ProfiNet Converter

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll poʻo le faʻasalalauga faʻapitoa ile ProfiNet Converter

    ODOT-PNM02 V2.1

    Modbus (matai / pologa, RTU / ASCII) i ProfiNET, 2 port serial port (RS485 / RS232 / RS422), lagolago 50 slots, 200 poloaiga i le faitotoa TIA (e ala i polokalama faakomepiuta), lagolago MAX 60 pologa

    ♦ Lagolagoina le suiga o le protocol i le va o Modbus ma PROFINET

    ♦ Lagolago 2 * RS485 / RS232 poʻo le 1 * RS422

    ♦ Lagolago Modbus matai poʻo le pologa, ma lagolagoina RTU poʻo ASCII

    ♦ Lagolago le vevela galue o -40〜85°C

    ♦ Lagolago vaega o faamatalaga: 2 serial Modbus-RTU / ASCII i PROFIBUS faitotoa ma Max.fa'aoga 1440 paita ma Max.gaosiga 1440 paita

    ♦ Lagolago tasi ki le toe setiina

    ♦ ODOT-PNM02 V2.0 lagolago avanoa aupito maualuga: 50

    ♦ ODOT-PNM02 V2.1 lagolago 60 pologa (200 faitau ma tusi poloaiga)

  • ODOT-S1E1 V2.0: Ulufale Fa'asologa

    ODOT-S1E1 V2.0: Ulufale Fa'asologa

    O se tagata liliu mai atiina ae e Sichuan Odot Automation System Co., LTD i le va o RS232 / 485/422 ma TCP / UDP.This converter protocol e mafai ona faigofie ona fesootai masini tau telefoni i Ethernet ma iloa le faaleleia o fesootaiga o masini uafu serial.

    E lagolagoina e le Protocol converter le galuega o le "fa'asalalauina o fa'amatalaga", lea e mafai ona fa'atulagaina o se tagata fa'atau po'o se fa'aumau.O lenei galuega e mafai ona faigofie ona iloa le fesoʻotaʻiga faʻamatalaga i le va o le PLC, server ma isi masini Ethernet ma le faʻaogaina o masini tau telefoni.

    Lagolago le TCP server ma le TCP client felauaiga manino
    Lagolagoina UDP fa'asalalauga manino ma va'a fa'asologa fa'asologa
    Lagolagoina felauaiga manino ma pe leai foi se protocol.O le fa'asalalauga manino fa'akomepiuta e lagolagoina le MODBUS RTU/ASCII
    Lagolagoina fa'asologa o fa'asologa o su'esu'ega a le WEB (Tulaga masani) Fa'asologa o le pa'u o le port serial 1200 i le 115200 bps

  • MG-CANEX CANopen i Modbus TCP converter

    MG-CANEX CANopen i Modbus TCP converter

    MG-CANEX Protocol Converter

    CANopen i le Modbus TCP protocol converter

    MG-CANEX o se fa'aliliuga fa'akomepiuta mai CANopen i le Modbus TCP.O le masini e taʻalo o le matai i le fesoʻotaʻiga CANopen ma e mafai ona faʻafesoʻotaʻi i masini pologa CANopen masani.O le faʻasalalauga faʻamatalaga e lagolagoina le PDO, SDO, ma le faʻatonutonuina o mea sese e lagolagoina le Heartbeat.E lagolagoina synchronous ma asynchronous fe'au auina atu.

    I le avea ai o se TCP server i le Modbus TCP network, e mafai ona maua le masini e le 5 TCP clients i le taimi e tasi, ma e mafai ona fesoʻotaʻi atu i le PLC controller ma ituaiga eseese o polokalama faʻapipiʻi.E mafai fo'i ona fa'afeso'ota'i le transceiver opitika ma iloa ai le felauaiga o fa'amatalaga mamao.

  • ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Feso'ota'iga ile EtherNet

    ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Feso'ota'iga ile EtherNet

    ♦ Faʻapipiʻi i luga o le PPI / MPI / PROFIBUS uafu fesoʻotaʻiga o le PLC, e masani lava e aunoa ma le faʻaogaina o le eletise mai fafo

    ♦ Lagolago Siemens S7 Ethernet avetaavale fesoʻotaʻiga, e aofia ai MicroWIN, STEP7, TIA Portal, WinCC ma isi.

    ♦ Faʻatasi ma le Modbus-TCP server, Modbus faʻamaumauga e mafai ona otometi pe faʻasaʻo i le faafanua e resitala ai S7-200/300/400

    ♦ fesoʻotaʻiga S7TCP ma fesoʻotaʻiga Modbus-TCP e mafai ona iloa i le taimi e tasi

    ♦ E oʻo atu i le 32 fesoʻotaʻiga komepiuta talimalo e lagolagoina

    ♦ MPI i le S7 Ethernet / Modbus-TCP converter

    ♦ Lagolagoina le toe setiina o le tasi-Ki

  • ODOT-DPM01: Modbus-RTU i le Profibus-DP Converter

    ODOT-DPM01: Modbus-RTU i le Profibus-DP Converter

    ♦ Lagolagoina le suiga o faʻasalalauga i le va o Modbus ma PROFIBUS

    ♦ Lagolago RS485, RS422 ma Rs232

    ♦ Lagolago Modbus matai ma pologa, ma lagolagoina RTU poʻo ASCII

    ♦ Lagolago siosiomaga galue o -40 ~ 85 ° C

    ♦ PROFIBUS-DP: Max.Ulufale 244 paita, Max.Tuuina atu 244 paita

    ♦ DPM01: 1-way Modbus i le PROFIBUS pologa faitotoʻa, aofaʻi o faʻaoga ma gaioiga e 288 paita.

    ♦ DPM02: (customization) 1-way Modbus-RTU i le PROFIBUS pologa faitotoʻa, aofaʻi o faʻaoga ma outputis488 bytes.

  • ODOT-S2E2: 2 Serial Modbus RTU/ASCII i Modbus TCP Converter

    ODOT-S2E2: 2 Serial Modbus RTU/ASCII i Modbus TCP Converter

    ♦ Lagolagoina le suiga o faʻasalalauga i le va o Modbus-RTU ma Modbus-TCP

    ♦ Lagolagoina le feso'ota'iga a le 5 TCP clients i le taimi e tasi

    ♦ ODOT-S2E2 lagolago 2 * RS485

    ♦ ODOT-S4E2 lagolagoina uaea o RS485/RS232/RS422

    ♦ O laina ta'itasi e lagolagoina Modbus masterand pologa

    ♦ ODOT-S2E2:2 faasologa Modbus-RTU/ASCII i Modbus-TCP Server faitotoa

    ♦ ODOT-S4E2:4 faasologa Modbus-RTU/ASCII i Modbus-TCP Server faitotoa

    ♦ Lagolago tasi ki le toe setiina

    ♦ Auala galue faitotoa: Fa'asalalauga manino, fa'afanua tuatusi

  • ODOT-S4E2: 4 Serial Modbus RTU/ASCII i le Modbus TCP converter

    ODOT-S4E2: 4 Serial Modbus RTU/ASCII i le Modbus TCP converter

    ♦ Lagolagoina le suiga o faʻasalalauga i le va o Modbus-RTU ma Modbus-TCP

    ♦ Lagolagoina le feso'ota'iga a le 5 TCP clients i le taimi e tasi

    ♦ ODOT-S2E2 lagolago 2 * RS485

    ♦ ODOT-S4E2 lagolagoina uaea o RS485/RS232/RS422

    ♦ O laina ta'itasi e lagolagoina Modbus masterand pologa

    ♦ ODOT-S2E2:2 faasologa Modbus-RTU/ASCII i Modbus-TCP Server faitotoa

    ♦ ODOT-S4E2:4 faasologa Modbus-RTU/ASCII i Modbus-TCP Server faitotoa

    ♦ Lagolago tasi ki le toe setiina